Sachin Sharma

PhD Research Scholar at IIT Jammu

Sachin Sharma

Sachin Sharma

PhD Research Scholar, Electrical Engineering

Indian Institute of Technology Jammu

Ultra-low-power analog and mixed-signal CMOS design for implantable biomedical devices, from amplifiers, references and regulators to the digital control and telemetry of a pacemaker system-on-chip.
Portrait of Sachin Sharma

About Me

I am a PhD research scholar in the Department of Electrical Engineering at IIT Jammu, working on the Implantable Pacemaker (iPACE) Chip project under the C2S Programme of the Ministry of Electronics and Information Technology (MeitY), Government of India.

My research centres on low-power analog and mixed-signal CMOS building blocks: operational transconductance amplifiers, bandgap references and low-dropout regulators. I also work on the telemetry and digital control architecture of implantable devices.

Before my PhD, I completed an M.E. in Power Systems at Panjab University, Chandigarh, and a B.Tech in Electrical Engineering at Moradabad Institute of Technology.

9.77 / 10PhD coursework CGPA
5 yearsGATE EE qualified, 2019–2023
UPSC ESEMains qualified, 2023

News

  • Presenting a low-power five-stage RISC-V processor for pacemaker SoCs at iSES 2026, NIT Goa (15–17 December).
  • Paper on a 1.8 V, 0.336 µA quiescent-current LDO accepted at IEEE APCCAS 2026, Fukuoka, Japan.
  • Multiple and variable reference voltage generator published in Integrated Circuits and Systems.
  • Appointed Vice-Chair of the IEEE Student Branch Chapter at IIT Jammu.

Research

Analog and mixed-signal IC design

CMOS analog building blocks, subthreshold techniques, amplifiers, voltage references and power management.

OTABGRLDO

Biomedical integrated circuits

Low-power circuits for implantable systems, with a focus on pacemaker sensing and system integration.

iPACEAFESoC

Digital systems and VLSI

RTL design, digital architecture, processor implementation, protocol control and verification.

VerilogRISC-VRTL

Implant telemetry

Near-field inductive communication and low-data-rate control and data-transfer architecture for implants.

Inductive linkCRC-8FSM

Publications

  1. 1.8 V LDO with 71.713 mV dropout and 0.336 µA quiescent current for implantable pacemaker SoC

    Sachin Sharma, Ashraf Ansari, Ambika Prasad Shah

    IEEE Asia Pacific Conference on Circuits and Systems (APCCAS), 2026

    Accepted
  2. A low-power CMOS-based multiple and variable reference voltage generator circuit

    R. Khola, S. Sharma, A. P. Shah

    Integrated Circuits and Systems (ICAS), 2026

    PublishedDOI: 10.23919/ICS.2026.3660786
  3. A 1.158 µW dual-output, 33.45/47.07 ppm/°C and 0.184/0.037 %/V, resistor-less CMOS bandgap reference for implantable devices

    Ashraf Ansari, Sachin Sharma, Ambika Prasad Shah

    IEEE Transactions on Very Large Scale Integration (VLSI) Systems

    Under review
  4. Leakage power attack-resilient 1 Kb split 8T SRAM architecture with enhanced half-select stability

    Sandeep Kour, Sachin Sharma, Ambika Prasad Shah

    IEEE Transactions on Circuits and Systems II: Express Briefs

    Under review

Projects

Analog and mixed-signal

1.158 µW

Resistor-less dual-output bandgap reference

CMOS reference for implantable devices with 1.232 V and 0.820 V outputs.

180 nm CMOSUnder review, TVLSI
0.336 µA

1.8 V low-dropout regulator

Low-quiescent-current LDO for a pacemaker SoC with 71.713 mV dropout.

180 nm CMOSAPCCAS 2026
OTA

Low-power OTA for a biomedical front end

Telescopic-cascode OTA with an NMOS input pair in subthreshold operation.

SCL 180 nmAnalog front end
VREF

Multiple and variable reference generator

Low-power CMOS circuit generating multiple and variable reference voltage levels.

CMOSICAS 2026

Digital and systems

RV32I

Five-stage pipelined RISC-V processor

Low-power RV32I core designed for an implantable pacemaker SoC.

VerilogiSES 2026
CRC-8

Pacemaker telemetry controller

RTL for implant-side and external-side communication: framing, command decoding, CRC-8 checking and data selection.

VerilogFSM
8T

Attack-resilient split 8T SRAM

1 Kb SRAM resilient to leakage-power attacks, with improved half-select stability.

SRAMUnder review, TCAS-II
FPGA

FPGA verification on Basys 3

Hardware verification of controller interfaces using switches, serial loopback and clock-generation changes.

VivadoBasys 3

Conferences

Dec 2026

iSES 2026, NIT Goa, India

Paper: “Low-power five-stage RISC-V processor for implantable pacemaker SoC.” 15–17 December 2026.

2026

IEEE APCCAS 2026, Fukuoka, Japan

Paper: “1.8 V LDO with 71.713 mV dropout and 0.336 µA quiescent current for implantable pacemaker SoC.”

Education

2023 – now

Ph.D. in VLSI

Indian Institute of Technology Jammu · CGPA 9.77 / 10

2021

M.E. in Power Systems

Panjab University, Chandigarh · CGPA 7.85 / 10 · 2nd rank

2018

B.Tech. in Electrical Engineering

Moradabad Institute of Technology · 84.22% · 1st rank

Service and teaching

  • Vice-Chair, IEEE Student Branch Chapter, IIT Jammu (2025–2026)
  • Teaching assistant for Basic Electrical and Electronics, Software Tools Lab, and ASIC Design Flow

Honours

  • Qualified UPSC Engineering Services Examination (Mains), 2023
  • Qualified GATE Electrical Engineering every year from 2019 to 2023
  • MHRD scholarship on the basis of GATE 2019

Certifications

  • Cadence Virtuoso Schematic Editor S1: Creating Design Schematics (vIC25.1)
  • Public Speaking Training and Facilitator, Udemy, 2023

Skills

EDA tools

Cadence Virtuoso, Calibre, Cadence Genus, Innovus, NC Launch, LTspice

Hardware and programming

Verilog, RV32I, Vivado, C, Embedded C

Analysis

MATLAB, OriginLab, Linux

Domains

Analog CMOS, mixed-signal IC, low-power design, RTL design, FPGA verification, biomedical SoC

Contact

I am glad to hear about research collaborations, academic discussions and opportunities in analog and mixed-signal design.

Request my CV

Please leave your name and an email address or phone number. Your details go only to me.